您所在位置:法邦网 > 法律法规 > 法规浏览

管理我的法规库

哇,我可以拥有自己的法规库!

法规提交

如果您发现我们没有收录到的法规,您可以在此提交。提交后我们会即时把它收录上,感谢您参与维护我们共同的法规库。
【法规名称】 
【法规编号】 68913  什么是编号?
【正  文】

第12页 CAP 265 PEAK TRAMWAY ORDINANCE

[接上页]

  (Enacted 1989)
  
  Cap 265A reg 25 Company not to operate tramway without adequate rescue facilities and equipment
  
  (1) The company shall, to the satisfaction of the Director, provide adequate equipment and facilities for the rescue of passengers in the event of an accident or emergency.
  
  (2) Without prejudice to the generality of subregulation (1), the company shall ensure that-
  
  (a) rescue equipment is located at suitable points along the length of the tramway;
  
  (b) all rescue equipment is adequately protected from damage, deterioration by weather and loss by theft.
  
  (Enacted 1989)
  
  Cap 265A reg 26 Company to replace hauling rope
  
  The company, upon being informed by the engineering superintendent of the existence of a matter referred to in regulation 11(1)(a) or (b), shall immediately replace the hauling rope or take other appropriate safety measures, as the case may be.
  
  (Enacted 1989)
  
  Cap 265A reg 27 Company to maintain safety of persons using or being in vicinity of tramway
  
  (1) The company shall, to the satisfaction of the Director, provide reasonable numbers of personnel and facilities for the control and safety of persons using, or being in the vicinity of, the tramway.
  
  (2) The company shall ensure that arrangements are made at each terminal on the tramway for the marshalling and control of persons using or intending to use the tramway so as to provide for safe and orderly embarkation and disembarkation.
  
  (3) Except in an emergency, the company shall not use any place other than its stations for the purpose of taking up or depositing passengers.
  
  (Enacted 1989)
  
  Cap 265A reg 28 Company to ensure safety generally
  
  The company shall ensure that-
  
  (a) all electric circuits, overload devices, circuit breakers, switchgear and protective devices are kept in a safe and proper state of repair and are examined in accordance with these regulations and good electrical engineering practice;
  
  (b) every station along the tramway is adequately lit when the tramway is in operation;
  
  (c) all rails and barriers used for the marshalling and control of passengers are kept at all times in a good state of repair;
  
  (d) all areas within a station are kept in a good state of repair and in a clean and orderly condition and that all floors within a station are kept in a non-slippery condition;
  
  (e) all guards and other devices for the protection of persons employed on the tramway and of the public are kept in a safe state of repair and are not removed;
  
  (f) no tramcar is used for the carriage of members of the public if-
  
  (i) the tramcar door interlocking safety system is not in working order; or
  
  (ii) any structural part thereof is deformed or broken;
  
  (g) notices in Chinese and in English are displayed in every tramcar and kept in good condition-
  
  (i) stating the maximum number of passengers permitted to be carried;
  
  (ii) stating the maximum weight permitted to be carried;
  
  (h) notices in Chinese and in English are displayed at every station and kept in good condition warning of any thing that is or is likely to be a mechanical or electrical danger to persons being in or in the vicinity of the station;
  
  (i) protection against injury of persons employed by the company in the operation of the tramway is provided by-
  
  (i) the display of notices in Chinese and in English warning of any thing that is or is likely to be a mechanical or electrical danger to such persons;
  
  (ii) the issue of safety belts to be worn by such persons when working at height or on a steep slope.
  
  (Enacted 1989)
  
  Cap 265A reg 29 Company to provide first aid at terminals
  
  (1) The company shall provide and maintain at each terminal a first aid box containing the items listed in the Schedule.
  
  (2) The company shall ensure that-
  
  (a) the items in the first aid box are maintained in a serviceable and sanitary condition;
  
  (b) all materials for dressings in the first aid box are those designated in, and are of a grade not lower than the standards specified by, the British Pharmaceutical Code or by any supplement to it;
  
  (c) nothing except appliances and requisites for first aid are kept in a first aid box; and
  
  (d) each first aid box is clearly and legible marked "FIRST AID" and "急救箱".
  
  (Enacted 1989)
  
  Cap 265A reg 30 Company to furnish information
  
  (1) The company shall, as soon as practicable, furnish to the Director a copy of each of the following-
  
  (a) the written report of the surveyor provided in accordance with regulation 4(1);
  
  (b) any written report of the engineering superintendent provided in accordance with regulation 8;
  
  (c) the maintenance programme prepared in accordance with regulation 9;
  
  (d) any training programme conducted by the company for operators in relation to regulation 17(2); and
  
  (e) the operation and maintenance manuals mentioned in regulation 24(1).(2) The company shall upon request by the Director afford to him sufficient facilities for obtaining information with respect to the operation of the tramway for the carriage of passengers and shall, in such manner and at such times as the Director may reasonably require, furnish him with reports, records, schedules, logs, manuals required to be kept or made under these regulations and other information with respect thereto and afford to him facilities for the verification of information furnished.
此法规有错误,我来纠正。请点击在此 提交错误内容或者您纠正的内容!
回到顶部
法规搜索:
法律法规  Copyright ©2007-2019 Fabao365.com 版权所有
|
京ICP备10210683号
|
京公网安备11010802013176号
|
客服电话:15811286610