CAP 403B OZONE LAYER PROTECTION (CONTROLLED REFRIGERANTS) REGULATION


  (Cap 403, section 16)
  
  [1 January 1994] G.N. 4794 of 1993
  
  (L.N. 158 of 1993)
  
  Cap 403B s 1 (Omitted as spent)
  
  (Omitted as spent)
  
  Cap 403B s 2 Interpretation
  
  In this Regulation, unless the context otherwise requires-
  
  "controlled refrigerant" (受管制制冷剂) means a scheduled substance which the Director has by notice in the Gazette, declared to be a controlled refrigerant;
  
  "motor vehicle" (汽车) means a mechanically propelled vehicle for use on roads;
  
  "motor vehicle air-conditioner" (汽车空调机) means an air-conditioner or heat pump that is designed to cool or heat the driver's or passenger's compartment of a motor vehicle and that utilizes for that purpose a controlled refrigerant;
  
  "recover" (回收) means to remove a controlled refrigerant from a refrigeration equipment or motor vehicle air-conditioner and to store it in a container designed for the purpose of storing refrigerants;
  
  "recycle" (循环使用) means, in relation to a controlled refrigerant, to purify or distil it, or to treat it in any other way so as to make it suitable for reuse;
  
  "refrigerant charge" (制冷剂量), in relation to refrigeration equipment, means the maximum quantity of controlled refrigerant the refrigeration equipment is intended to hold for the purposes of its operation, and for this purpose that quantity shall be determined-
  
  (a) by reference to the design and specifications of the refrigeration equipment; or
  
  (b) in the absence of information respecting the design and specifications of the refrigeration equipment, by a method of estimation commonly used by manufacturers of refrigerators or air-conditioners;"refrigerant recycling equipment" (制冷剂回收再造机) means equipment designed for recovering or treating refrigerant;
  
  "refrigeration equipment" (冷冻设备) means a machine or machinery that-
  
  (a) is designed to cool or freeze anything or to function as a heat pump;
  
  (b) utilizes for that purpose a controlled refrigerant; and
  
  (c) is installed in premises other than domestic premises,but does not include equipment in which the refrigerant charge is 50 kg or less or a motor vehicle air-conditioner.
  
  (Enacted 1993)
  
  Cap 403B s 3 Director to declare controlled refrigerant
  
  The Director may, by notice in the Gazette, declare any scheduled substance to be a controlled refrigerant for the purposes of this Regulation.
  
  (Enacted 1993)
  
  Cap 403B s 4 Approval of refrigerant recycling equipment
  
  The Director may for the purpose of this Regulation approve any type of refrigerant recycling equipment and may signify his approval by notice in the Gazette.
  
  (Enacted 1993)
  
  Cap 403B s 5 Prohibition on releasing controlled refrigerant
  
  (1) A person who allows or causes any controlled refrigerant used or intended for use in a refrigeration equipment or motor vehicle air-conditioner to escape into the atmosphere commits an offence and is liable to a fine of $100000.
  
  (2) It is a defence for a person charged with an offence under this section to prove that-
  
  (a) the escape occurred in the course of-
  
  (i) transferring the controlled refrigerant from refrigeration equipment or from a motor vehicle air-conditioner to a container designed for the purpose of storing refrigerants;
  
  (ii) recycling the controlled refrigerant;
  
  (iii) transferring the controlled refrigerant from a container designed for the storage thereof into refrigeration equipment or into a motor vehicle air-conditioner; or
  
  (iv) disposing of the controlled refrigerant by a method approved by the Director by notice in the Gazette,
  
  and that he took all reasonable precautions and exercised all due diligence to prevent the escape to occur;(b) the escape occurred by reason of an accident or other cause beyond his control and that he took all reasonable precautions and exercised all due diligence to prevent the escape to occur; or
  
  (c) it was necessary to allow the escape to occur by reason of an emergency and in order to prevent danger to the health or safety of any person.
  
  (Enacted 1993)
  
  Cap 403B s 6 Control of recycling of controlled refrigerant
  
  (1) No person shall recover, recycle or otherwise treat or cause or allow to be recovered, recycled or otherwise treated a controlled refrigerant unless-
  
  (a) refrigerant recycling equipment approved by the Director under section 4 is used for recovering or recycling the controlled refrigerant; and
  
  (b) the equipment is used-
  
  (i) in accordance with any instruction issued by the manufacturer of the equipment; and
  
  (ii) in a manner as may be specified by notice in the Gazette by the Director.(2) A person who contravenes this section commits an offence and is liable to a fine of $100000.
  
  (Enacted 1993)
  
  Cap 403B s 7 Records to be kept in relation to refrigeration equipment
  
  (1) The owner or occupier of premises in which there is refrigeration equipment shall keep in the premises up-to-date records of-
  
  (a) the dates on which any controlled refrigerant was removed from that equipment during servicing or repairing that equipment;