CAP 311B AIR POLLUTION CONTROL (DUST AND GRIT EMISSION) REGULATIONS


  (Cap 311 section 43)
  
  [1 January 1974]
  
  (L.N. 190 of 1973)
  
  ------------------------------------------------------------------------------------------
  
  Note:
  
  These regulations were made under the repealed Clean Air Ordinance and, by virtue of section 36(1) of the Interpretation and General Clauses Ordinance (Cap 1), continue to have the like effect as if they had been made under the present Air Pollution Control Ordinance (Cap 311).
  
  Cap 311B reg 1 Citation
  
  These regulations may be cited as the Air Pollution Control (Dust and Grit Emission) Regulations.
  
  (17 of 1983 s. 50; L.N. 262 of 1987)
  
  Cap 311B reg 2 Interpretation
  
  In these regulations, unless the context otherwise requires-
  
  "dust" (尘埃) means particles of solid matter which will pass through a sieve of 75 micrometre nominal aperture in conformity with BS 410: 1986 of the British Standards Institution; (L.N. 262 of 1987)
  
  "grit" (砂砾) means particles of solid matter which are retained in a sieve of 75 micrometre nominal aperture in conformity with BS 410: 1986 of the British Standards Institution; (L.N. 262 of 1987)
  
  "person using a liquid fuel" (使用液体燃料的人) includes a person who is the owner or has possession or control of the burner of the furnace, oven or industrial plant in which the liquid fuel is used;
  
  "rated capacity" (额定功率) in relation to a burner of any furnace, oven or industrial plant means the manufacturer's published capacity rating of the burner or, if such capacity rating is not available, the capacity rating of the burner as measured by a method approved by the Authority; (17 of 1983 s. 50)
  
  "sample" (样本) means a gross sample composed of a number of increments taken separately or cumulatively;
  
  "viscosity" (黏度) in relation to a liquid fuel means the strength or resistance of the liquid fuel offered to shear, such strength or resistance being determined by the rate of flow of the liquid fuel in given circumstances and at given temperatures expressed in centistokes or by any of the test procedures contained in the First Schedule. (L.N. 262 of 1987)
  
  (L.N. 262 of 1987)
  
  Cap 311B reg 3 Provision of sampling points
  
  (1) If it appears to the Authority that a sampling point for the purpose of taking samples of dust and grit under regulation 6(1)(a)(i) or (ii) should be provided he may serve a notice in writing upon the occupier of the premises upon which any furnace, oven, industrial plant, chimney or flue is situated- (L.N. 262 of 1987)
  
  (a) requiring him, within 60 days of service of the notice or such further period as the Authority may grant, to provide and install at his own cost such sampling point as may be specified in the notice; and
  
  (b) specifying the design and position of the sampling point required to be installed which shall, if provided for the purpose of regulation 6(1)(a)(i) and in so far as is reasonably practicable, comply with Reference Method 5 of the United States of America Environmental Protection Agency for determination of particulate emission from stationary sources. (L.N. 262 of 1987)(2) If any person fails to comply with the requirements or specifications of a notice served on him under paragraph (1), he shall be guilty of an offence and shall be liable on conviction to a fine of $5000 and, in addition, to a fine of $50 for each day during which it is proved that the offence has continued:
  
  Provided that if an appeal is made under section 31 of the Ordinance, no offence shall be deemed to have been committed until after such appeal is determined or abandoned.
  
  (17 of 1983 s. 50)
  
  Cap 311B reg 4 Duties of occupier
  
  (1) The occupier of the premises upon which a sampling point is installed shall make provision for safe access to the sampling point and shall maintain the sampling point in good condition.
  
  (2) If any person fails to comply with paragraph (1), he shall be guilty of an offence and shall be liable on conviction to a fine of $1000.
  
  Cap 311B reg 5 Use of liquid fuel
  
  (1) Except with the written permission of the Authority, no person shall use or cause or permit to be used in a burner of a furnace, oven or industrial plant a liquid fuel with a viscosity when delivered to the burner tip or point of ignition exceeding 30 centistokes or an equivalent viscosity. (17 of 1983 s. 50; L.N. 262 of 1987)
  
  (2) The Authority shall not grant permission under paragraph (1) to use a liquid fuel unless he is satisfied that the use of that fuel in a burner of a furnace, oven or industrial plant will not result in the emission of dark smoke from that furnace, oven or industrial plant. (17 of 1983 s. 50)
  
  (3) Any person who contravenes paragraph (1) shall be guilty of an offence and shall be liable on conviction to a fine of $5000.
  
  Cap 311B reg 6 Power to take samples of dust and grit and take samples of liquid fuel
  
  (1) The Authority or an authorized officer may- (17 of 1983 s. 50)
  
  (a) take a sample of dust and grit emitted from any furnace, oven or industrial plant, or passing through any chimney or flue, for the purpose of-