第5页 CAP 172A PLACES OF PUBLIC ENTERTAINMENT REGULATIONS

[接上页]

  (2) Waterclosets shall not, save where unavoidable, be approached directly from the auditorium or from any space in which the public await admission.
  
  (3) If lengthy cinematograph displays are to be given in any place of public entertainment, one of the watercloset fitments or urinals required, by the Building (Standards of Sanitary Fitments, Plumbing, Drainage Works and Latrines) Regulations (Cap 123 sub. leg.), to be provided for the persons employed or likely to be employed therein shall be provided contiguous to the operating enclosure.
  
  (G.N.A. 85 of 1959)
  
  Cap 172A reg 57 (Repealed L.N. 193 of 1996)
  
  Cap 172A reg 58 (Repealed L.N. 193 of 1996)
  
  Cap 172A reg 59 Dustbins
  
  An adequate number of metal bins or receptacles with properly fitting covers shall be provided for dust and refuse. Such receptacles shall be maintained in a clean and wholesome condition, in an open area or other suitable place.
  
  Cap 172A reg 60 Copy of certificate issued for the purposes of the Electricity (Wiring) Regulations to be furnished
  
  Lighting, cooling, electrical, ventilating and
  
  mechanical installations
  
  (1) Where-
  
  (a) a licence is granted or renewed under regulation 3; and
  
  (b) a fixed electrical installation is installed in the premises to which the licence relates, then for so long as the licence remains in force, the licensee shall, as regards each successive period of 12 months beginning on the date on which the licence was granted or renewed, as the case may be, furnish to the licensing authority a copy of a certificate issued within that period for the purposes of regulation 20 of the Electricity (Wiring) Regulations (Cap 406 sub. leg.) and relating to the fixed electrical installation, and in case more than 1 such certificate is issued within such period, the copy to be furnished under this regulation is a copy of the certificate which is later or, where appropriate, latest in date.
  
  (2) The requirements of paragraph (1) shall, as regards a particular period of 12 months, be complied with not later than 3 months after the expiration of that period.
  
  (L.N. 193 of 1996)
  
  Cap 172A reg 61 (Repealed L.N. 193 of 1996)
  
  Cap 172A reg 62 (Repealed L.N. 193 of 1996)
  
  Cap 172A reg 63 (Repealed L.N. 193 of 1996)
  
  Cap 172A reg 64 (Repealed L.N. 193 of 1996)
  
  Cap 172A reg 65 (Repealed L.N. 193 of 1996)
  
  Cap 172A reg 66 (Repealed L.N. 193 of 1996)
  
  Cap 172A reg 67 (Repealed L.N. 193 of 1996)
  
  Cap 172A reg 68 (Repealed L.N. 193 of 1996)
  
  Cap 172A reg 69 (Repealed L.N. 193 of 1996)
  
  Cap 172A reg 70 (Repealed L.N. 193 of 1996)
  
  Cap 172A reg 71 (Repealed L.N. 193 of 1996)
  
  Cap 172A reg 72 (Repealed L.N. 193 of 1996)
  
  Cap 172A reg 73 (Repealed L.N. 193 of 1996)
  
  Cap 172A reg 74 (Repealed L.N. 193 of 1996)
  
  Cap 172A reg 75 (Repealed L.N. 193 of 1996)
  
  Cap 172A reg 76 (Repealed L.N. 193 of 1996)
  
  Cap 172A reg 77 Switchboards, control apparatus, etc.
  
  (1)-(2) (Repealed L.N. 193 of 1996)
  
  (3) Switch and fuse boards and other controlling apparatus shall, wherever practicable, be installed in positions inaccessible to the public. If the licensing authority agrees in writing to such apparatus being installed within reach of the public, arrangements shall be made to prevent interference by any unauthorized person. Cut-outs shall not be installed in positions where they may be visible to the assembled public.
  
  (4) Local switching for lighting shall be avoided as far as practicable in all parts of premises accessible to the public.
  
  (5) The rating of switches which are liable to frequent operation shall be for currents 50 per cent in excess of the maximum current of the main circuits or sub-circuits controlled.
  
  (6) When practicable motor-starting switch gear shall be installed close to the motor controlled thereby and shall be so placed that the motor is clearly visible to the operator. Any apparatus or switch provided for speed control or for stopping shall, if installed away from the motor, be so arranged that it cannot be used as a starter.
  
  If in any case the permission of the licensing authority in writing is given for the remote control of motors, a suitable isolating switch shall be installed close to the motor.
  
  (7)-(8) (Repealed L.N. 193 of 1996)
  
  Cap 172A reg 78 (Repealed L.N. 193 of 1996)
  
  Cap 172A reg 79 (Repealed L.N. 193 of 1996)
  
  Cap 172A reg 80 (Repealed L.N. 193 of 1996)
  
  Cap 172A reg 81 Machines
  
  (1) Generators and motors shall be designed for the particular purposes for which they are required and shall be installed only in approved positions.
  
  (2) Such machines, unless of the pipe-ventilated or flameproof type, shall be installed in enclosures constructed of fire-resisting materials and adequately ventilated.
  
  (3) Every such machine shall be fitted with a plate indicating the type, voltage, speed, capacity and, where applicable, the frequency and number of phases.
  
  Cap 172A reg 82 (Repealed L.N. 193 of 1996)
  
  Cap 172A reg 83 Radiators and convectors
  
  Radiators, convectors and other current-consuming devices shall not be installed except with the consent in writing of the licensing authority. If such a device be installed it shall be securely fixed in position and, if liable in any circumstances to reach a high temperature, shall be provided with a stout wire guard of close mesh, securely fixed and so arranged that no part of the guard is within 150 mm of any portion of the device which is at a high temperature. The metal framework and the guard shall be earthed.