第4页 CAP 369E MERCHANT SHIPPING (MINIMUM PASSENGER SPACE) REGULATIONS

[接上页]

  (d) be laid to the satisfaction of the Director.(10) The floors of every hospital or dispensary, other than in sanitary accommodation contained in or connected with any such hospital or dispensary, shall consist of-
  
  (a) linoleum, free from joints and laid to the satisfaction of the Director; or
  
  (b) a material, approved by the Director, not likely to be damaged by surgical spirits or other liquids used in the hospital or dispensary, laid to the satisfaction of the Director.
  
  Cap 369E reg 8 Safety measures - piping installations, notices, entrances and exits, hatchway openings and ventilation trunks
  
  (1) No steam supply or exhaust pipe for steering gear, winches, rice boilers or other similar equipment shall be fitted to pass through any compartment or space allocated for the accommodation of passengers in any ship to which these regulations apply:
  
  Provided that, where the Director is satisfied that any alternative arrangement is unreasonable or impracticable in the circumstances, he may permit such pipes, if insulated and encased to his satisfaction, to be fitted to pass through passageways accessible to passengers, subject, in the case of supply pipes, to the following conditions-
  
  (a) the pipes shall be soundly constructed of solid drawn steel or other suitable material;
  
  (b) the pipes shall be of a scantling sufficient to withstand the maximum pressure from the ship's boiler system;
  
  (c) all connections in the pipes shall be by faced flanges properly jointed; and
  
  (d) the pipes shall be fitted with adequate drainage arrangements.(2) Every steam pipe, hot water pipe and calorifier in or serving any sanitary accommodation or hospital shall be efficiently lagged for the protection of any person from injury or discomfort.
  
  (3) Every piping system that is part of a smothering-gas or steam installation, which serves a compartment or space to which passengers have access or which has been allocated as accommodation for unberthed passengers shall-
  
  (a) for the purpose of guarding against inadvertent operation of the system whilst passengers are within such compartments or spaces, be fitted with an additional valve or cock, which can be locked; and
  
  (b) be made so as to enable a length of pipe outside such compartment or space, preferably adjacent to the control valve, to be removed.(4) Conspicuous notices indicating the precautionary measures to be adopted in case of an emergency shall be posted in every compartment or space referred to in paragraph (3) and also in the control station.
  
  (5) The means of access to and egress from a space or compartment allocated for the accommodation of passengers shall be situated so that in the event of a fire in any cargo space, storage space, lamp room, galley or machinery space, such fire will not prevent the escape of passengers from any such space or compartment.
  
  (6) Every hatchway within any space allocated for the accommodation of unberthed passengers shall be guarded by portable stanchions of a height of not less than 42 inches, spaced at suitable intervals and fitted with chains, or equivalent, and so spaced that the vertical distance in between does not exceed 12 inches, the lowest line of same being not more than 9 inches from the deck or by other similar means when any such hatchway is open for the purpose of working cargo or for any other purpose.
  
  (7) Any ventilator trunk to a cargo space or tank shall be constructed of steel or other suitable material and shall, if it passes through any space or compartment allocated for the accommodation of passengers, be gastight and suitably insulated.
  
  (8) Any ventilator trunk used for the natural or mechanical ventilation of any space or compartment allocated for the accommodation of passengers shall not be used for the ventilation of any space other than space or compartments used exclusively for the accommodation of passengers or crew.
  
  Cap 369E reg 9 Ventilation of sanitary accommodation
  
  (1) Sanitary accommodation shall be so arranged as to prevent, as far as possible, any effluvia from such sanitary accommodation penetrating into any space or compartment allocated for the accommodation of passengers.
  
  (2) In the case of any trunked ventilation system used to provide ventilation for sanitary accommodation in addition to passenger accommodation, each trunk leading to the sanitary accommodation shall be fitted with apparatus to prevent the dissemination of effluvia from the sanitary accommodation to other spaces when the ventilation system is not in use.
  
  (3) In no case shall a natural ventilation trunk be used to provide ventilation common to both passenger accommodation and sanitary accommodation.
  
  Cap 369E reg 10 Provision for spaces in which livestock may be carried
  
  (1) Where livestock are carried on a ship to which these regulations apply, such arrangements as are approved by the Director shall be made for separating the spaces in which the livestock are carried from any space allocated for the accommodation of passengers.