第4页 CAP 470 BUILDERS' LIFTS AND TOWER WORKING PLATFORMS (SAFETY) ORDINANCE

[接上页]

  (h) that the driving machine of a builder's lift or tower working platform is equipped with an effective driving machine brake that-
  
  (i) operates immediately to arrest the lift cage or platform, as the case may be, when the electrical circuit of any safety device is interrupted; and
  
  (ii) is capable of bringing the lift cage or platform, as the case may be, to rest under maximum load and at maximum speed and maintaining it in a stationary position,
  
  and that the driving machine brake is kept in good working order and a proper state of repair;(i) subject to paragraph (j), that a builder's lift or tower working platform is equipped with effective safety gear and an effective overspeed governor, and that the safety gear and overspeed governor are kept in good working condition and a proper state of repair;
  
  (j) where a tower working platform is not equipped with safety gear and an overspeed governor as required by paragraph (i), that it is equipped with an additional braking system which is capable of regulating its downward speed, and that the additional braking system is kept in good working condition and a proper state of repair;
  
  (k) that all safety switches used on a builder's lift or tower working platform are of a positive mechanically operated type and are kept in good working order and a proper state of repair;
  
  (l) that the travel of a lift cage or platform and, where applicable, the counterweight, shall be limited at the bottom by an effective buffer system;
  
  (m) that effective guards are provided for all moving parts of a builder's lift or tower working platform to prevent accidental human contact;
  
  (n) that all electrical components of a builder's lift or tower working platform are kept in a proper state of repair and are examined in accordance with the requirements of any laws relating to such components;
  
  (o) that a builder's lift or tower working platform is equipped with an audible emergency alarm that is-
  
  (i) activated from inside the lift cage or on the platform, as the case may be; and
  
  (ii) sufficiently loud to attract assistance from other persons on the construction site on which it is situated,
  
  and that the alarm is kept in good working condition and a proper state of repair;(p) that all structural and mechanical components of a builder's lift or tower working platform are kept in a proper state of repair.
  
  (Enacted 1995)
  
  Cap 470 s 10 Duties of owner
  
  The owner of a builder's lift or tower working platform shall ensure that the following requirements are complied with-
  
  (a) that the builder's lift or tower working platform is properly maintained, adequately supported and securely anchored;
  
  (b) that a notice in both English and Chinese with letters and characters not less than 30 millimetres in height is prominently displayed in the lift cage or on the platform stating-
  
  (i) the maximum number of persons; and
  
  (ii) the maximum weight,
  
  permitted to be carried, and that the notice is kept legible at all times;(c) that the lift cage and every landing is sufficiently well lit, whether by natural light or artificial light, to permit its safe use when the builder's lift is in operation;
  
  (d) that the platform is sufficiently well lit, whether by natural light or artificial light, to permit its safe use when the tower working platform is in operation;
  
  (e) that any part of the liftway that is accessible to persons is properly enclosed so as to prevent a person from being struck by the lift cage or platform;
  
  (f) that a builder's lift has a gate of robust construction-
  
  (i) for the lift cage; and
  
  (ii) at every point at which there is access to the liftway,
  
  and that all gates are kept in good working condition and a proper state of repair;(g) that a platform has a fence around its perimeter of robust construction with a minimum height of 1 metre, and that the fence is kept in a proper state of repair;
  
  (h) that the lift cage is of robust design and capable of safeguarding passengers against shearing and crushing by objects outside the lift cage, and that the lift cage is kept in a proper state of repair;
  
  (i) that effective guards are provided for all moving parts of a builder's lift or tower working platform to prevent accidental human contact;
  
  (j) that a builder's lift or tower working platform is equipped with an audible emergency alarm that is-
  
  (i) activated from inside the lift cage or on the platform, as the case may be; and
  
  (ii) sufficiently loud to attract assistance from other persons on the construction site,
  
  and that the alarm is kept in good working condition and a proper state of repair.
  
  (Enacted 1995)
  
  Cap 470 s 11 Codes of practice
  
  PART V
  
  CODES OF PRACTICE
  
  (1) The Director may establish codes of practice for lift work.
  
  (2) Where the Director establishes a code of practice or amends a code of practice already established, he shall publish a notice in the Gazette identifying the code that is established or amended, specifying the date on which it is to take effect and advising the place at which a copy of the code or amendment may be examined.
此法规有错误,我来纠正。请点击在此 提交错误内容或者您纠正的内容!