[接上页] (Enacted 1991) Cap 369Y reg 12 International shore connection Every ship of Class I of 500 tons or over shall be provided with at least one international shore connection which shall comply with the requirements of Schedule 1 to enable water to be supplied from another ship or from the shore to the fire main. Fixed provision shall be made to enable such a connection to be used on the port side and on the starboard side of the ship. (Enacted 1991) Cap 369Y reg 13 Application Expanded Cross Reference: 3, 4, 5, 6, 7, 8, 9, 10, 11, 12 Ships of Class II Regulations 3 to 12 inclusive shall apply to ships of Class II as they apply to ships of Class I. (Enacted 1991) Cap 369Y reg 14 Application Expanded Cross Reference: 3, 4, 5, 6, 7, 8, 9, 9A, 10, 11, 12 Ships of Class II(A) of 21.34 metres in length or over Regulations 3 to 12 inclusive shall apply to ships of Class IIA of 21.34 metres in length or over as they apply to ships of Class I. <* Note - Exp. X-Ref.: Regulations 3, 4, 5, 6, 7, 8, 9, 9A, 10, 11, 12 *> (Enacted 1991) Cap 369Y reg 15 Fire pumps, fire main, water service pipes, hydrants, hoses and nozzles Ships of Class II(A) of less than 21.34 metres in length Every ship of Class II(A) of less than 21.34 metres in length shall be provided in a position outside the machinery spaces with either a power or hand operated pump with a permanent sea connection and a hose with a 10 millimetres diameter dual-purpose nozzle capable of producing a jet of water having a throw of not less than 6 metres which can be directed on to any part of the ship. (Enacted 1991. L.N. 410 of 1995) Cap 369Y reg 16 Portable fire extinguishers Every ship of Class II(A) of less than 21.34 metres in length shall be provided with at least one portable fire extinguisher in each of the passenger spaces above the bulkhead deck, and with at least 2 such extinguishers in each of the crew spaces and in each of the passenger spaces below that deck. At least one portable fire extinguisher shall be available for use in any galley. (Enacted 1991) Cap 369Y reg 17 Machinery spaces of Category A and spaces containing oil fuel settling tanks (1) In every ship of Class II(A) of less than 21.34 metres in length there shall be provided in any space containing any oil-fired boiler, oil fuel settling tank or oil fuel unit, one or more foam fire extinguishers each of at least 45 litres capacity or carbon dioxide extinguishers each of at least 16 kilograms capacity. The extinguisher, or extinguishers, shall be sited so as to be readily accessible in the event of a fire and they shall be sufficient in number to enable foam or carbon dioxide to be directed on to any part of the boiler room or space containing any part of the oil fuel installation. In addition there shall be provided- (a) in each firing space and in each space which contains any part of any oil fuel installation at least 2 portable fire extinguishers suitable for extinguishing oil fires; (L.N. 410 of 1995) (b) in each firing space a receptacle containing at least 0.3 cubic metre of sand or other dry material suitable for extinguishing oil fires together with a scoop for its distribution, or alternatively, an additional portable fire extinguisher suitable for extinguishing oil fires; and (L.N. 410 of 1995) (c) in each boiler room not being part of an internal combustion machinery space- (i) at least 2 water fog applicators; (ii) at least one set of portable foam applicator unit complying with the provisions of Schedule 6; and (iii) a fixed fire-extinguishing system complying with the requirements of regulation 7(1) by 1 October 2000. (L.N. 410 of 1995)(2) (a) In every ship of Class II(A) of 15.24 metres in length or over but of less than 21.34 metres in length there shall be provided in each space containing internal combustion type propulsion machinery at least 5 portable fire extinguishers suitable for extinguishing oil fires, and every ship of Class II(A) of less than 15.24 metres in length shall be provided with at least 3 such portable fire extinguishers in such spaces; provided that where internal combustion machinery is situated in a space to which subregulation (1) applies, only 2 such portable fire extinguishers need be provided in addition to the extinguishers required by that subregulation. (L.N. 410 of 1995) (b) In each Category A machinery space containing internal combustion type machinery, there shall be provided in addition to the requirements of paragraph (a)- (i) at least 2 water fog applicators; (ii) at least one set of portable foam applicator unit complying with the provisions of Schedule 6; and (iii) a fixed fire-extinguishing system complying with the requirements of regulation 7(1) by 1 October 2000. (L.N. 410 of 1995)(3) In every ship of Class II(A) carrying more than 36 passengers, each member of the fire patrol shall be provided with a two-way portable radiotelephone apparatus. (L.N. 410 of 1995) (Enacted 1991) Cap 369Y reg 18 (No provision) |