[接上页] (4) Firemen's outfits shall be stored so as to be easily accessible and ready for use and where more than one fireman's outfit are carried they shall be stored in widely separated positions. (Enacted 1991) Cap 369X reg 40 International shore connection Every ship of Class VII of 1000 tons or over shall be provided with at least one international shore connection which shall comply with the requirements of Schedule 1 to enable water to be supplied from another ship, or from the shore, to the fire main and fixed provision shall be made to enable such a connection to be used on the port side and on the starboard side of the ship. (Enacted 1991) Cap 369X reg 41 Ships of Class VII of under 500 tons (1) This regulation applies to ships of Class VII of under 500 tons. (2) (a) Every such ship shall be provided with appliances in accordance with this regulation whereby at least one jet of water as required by these regulations can reach any part of the ship normally accessible to the passengers or crew while the ship is being navigated, and any store room and any part of any cargo space when empty. (b) Every such ship shall be provided with at least one fire pump operated by power which shall be capable of delivering at least one jet of water from any fire hydrant hose and nozzle provided in the ship, and which shall comply with the requirements of regulation 66. (c) In every such ship fitted with oil-fired boilers or internal combustion type propelling machinery there shall be provided in a position outside the spaces containing such boilers or machinery an additional fire pump and its source of power and sea connection. If such pump is operated by power, it shall comply with the requirements of paragraph (b) and if it is manually operated it shall be provided with a hose and 10 millimetres diameter nozzle through which it shall be capable of producing a jet of water having a throw of not less than 6 metres which can be directed on to any part of the ship. (d) In every such ship there shall be provided a fire main, water service pipes and hydrants which shall comply with the requirements of regulation 67 and at least 3 fire hoses and nozzles which shall comply with regulation 68. (e) In every such ship fitted with oil-fired boilers or internal combustion type propelling machinery there shall be provided a dual-spray nozzle suitable for use with the fire hoses required by paragraph (d).(3) Every such ship shall be provided with at least 3 portable fire extinguishers so situated as to be readily available for use in the accommodation and service spaces. (4) In every ship to which this regulation applies there shall be provided for the protection of any space containing any oil-fired boiler, oil fuel settling tank or oil fuel unit, at least one of the fixed fire extinguishing installations required by regulation 34(1). (5) In addition to the requirements of subregulation (4) there shall be provided- (a) in each boiler room and in each space which contains any part of any oil fuel installation, at least 2 portable fire extinguishers suitable for extinguishing oil fires; (b) in each firing space, a receptacle containing at least 0.3 cubic metre of sand or other dry material suitable for quenching oil fires together with a scoop for its distribution, or alternatively, an additional portable fire extinguisher suitable for extinguishing oil fires.(6) In every ship to which this regulation applies there shall be provided in any space containing internal combustion type machinery one portable fire extinguisher suitable for extinguishing oil fires for each 74.6 kW or part thereof of such machinery, except that no more than 7 such extinguishers shall be required in any one space and that alternatively there may be provided 2 such extinguishers together with either- (a) one foam fire extinguisher of at least 45 litres capacity; or (b) one carbon dioxide fire extinguisher of at least 16 kilograms capacity.(7) Every ship to which this regulation applies shall be provided with at least one fireman's outfit which shall comply with the requirements of regulation 71 and which shall contain a breathing apparatus of the air hose type. (Enacted 1991) Cap 369X reg 42 Expanded Cross Reference: 31, 32, 33, 34, 35, 36, 37, 37A, 38, 39, 40 Ships of Class VII(A) (1) Regulations 31 to 40 inclusive shall apply to every ship of Class VII(A) of 500 tons or over as they apply to ships of Class VII of 500 tons or over. <* Note - Exp. X-Ref.: Regulations 31, 32, 33, 34, 35, 36, 37, 37A, 38, 39, 40 *> (2) Every ship of Class VII(A) of less than 500 tons shall carry the fire appliances required by these regulations to be carried by ships of Class VII of under 500 tons. (Enacted 1991) Cap 369X reg 43 Expanded Cross Reference: 34, 35, 36, 37, 37A, 38, 39, 40 Tankers of Class VII(T) of 500 tons or over Regulations 31 and 32(1) and regulations 34 to 40 inclusive shall apply to every tanker of Class VII(T) of 500 tons or over. <* Note - Exp. X-Ref.: Regulations 34, 35, 36, 37, 37A, 38, 39, 40 *> |