[接上页] (Enacted 1991)___________________________________________________________________ Note: * This refers to the Code on Alarms and Indicators adopted by the International Maritime Organization by Resolution A.686(17). Cap 369X reg 12 Firemen's outfits (1) Every ship of Class I shall be provided with- (a) 2 firemen's outfits and in addition; (b) 2 firemen's outfits for every 80 metres (or part thereof) of the aggregate of the lengths of all passenger spaces and service spaces on the deck which carries such spaces or, if there is more than one such deck, on the deck which has the largest aggregate of such lengths. Every such outfit shall comply with the requirements of regulation 71. Two of them shall include breathing apparatus of the air-hose type and the remainder shall include breathing apparatus of the self-contained type.(2) In every ship of Class I carrying more than 36 passengers for each pair of breathing apparatus there shall be provided one water fog applicator which shall be stored adjacent to such apparatus. (Enacted 1991) Cap 369X reg 13 International shore connection Every ship of Class I of 1000 tons or over shall be provided with at least one international shore connection which shall comply with the requirements of Schedule 1 to enable water to be supplied from another ship, or from the shore, to the fire main and fixed provision shall be made to enable such a connection to be used on the port side and on the starboard side of the ship. (Enacted 1991) Cap 369X reg 14 Expanded Cross Reference: 3, 4, 5, 6, 7, 8, 9, 10, 10A, 11, 12, 13 Ships of Class II Regulations 3 to 13 inclusive shall apply to ships of Class II as they apply to ships of Class I. <* Note - Exp. X-Ref.: Regulations 3, 4, 5, 6, 7, 8, 9, 10, 10A, 11, 12, 13 *> (Enacted 1991) Cap 369X reg 15 Expanded Cross Reference: 3, 4, 5, 6, 7, 8, 9, 10, 10A, 11, 12, 13 Ships of Class II(A) of 21.34 metres in length or over Regulations 3 to 13 inclusive shall apply to ships of Class IIA of 21.34 metres in length or over as they apply to ships of Class I. <* Note - Exp. X-Ref.: Regulations 3, 4, 5, 6, 7, 8, 9, 10, 10A, 11, 12, 13 *> (Enacted 1991) Cap 369X reg 16 Fire pumps, fire main, water service pipes, hydrants, hoses and nozzles Ships of Class II(A) of less than 21.34 metres in length Every ship of Class II(A) of less than 21.34 metres in length shall be provided in a position outside the machinery spaces with a hand pump with a permanent sea connection, a hose with a 10 millimetres diameter nozzle, capable of producing a jet of water having a throw of not less than 6 metres which can be directed on to any part of the ship and a dual-purpose nozzle. (Enacted 1991. L.N. 412 of 1995) Cap 369X reg 17 Portable fire extinguishers Every ship of Class II(A) of less than 21.34 metres in length shall be provided with at least 1 portable fire extinguisher in each of the passenger spaces above the bulkhead deck, and with at least 2 such extinguishers in each of the crew spaces and in each of the passenger spaces below that deck. At least 1 portable fire extinguisher shall be available for use in any galley. (Enacted 1991) Cap 369X reg 18 Machinery spaces containing oil-fired boilers or oil burning equipment (1) In every ship of Class II(A) of less than 21.34 metres in length there shall be provided in any space containing any oil-fired boiler, oil fuel settling tank or oil fuel unit, one or more foam fire extinguishers each of at least 45 litres capacity or carbon dioxide extinguishers each of at least 16 kilograms capacity. The extinguisher, or extinguishers, shall be sited so as to be readily accessible in the event of a fire and they shall be sufficient in number to enable foam or carbon dioxide to be directed on to any part of the boiler room or spaces containing any part of the oil fuel installation. (2) In addition to the requirements of subregulation (1) there shall be provided- (a) in each firing space and in each space which contains any part of any oil fuel installation at least 2 portable fire extinguishers suitable for extinguishing oil fires; (b) in each firing space a receptacle containing at least 0.3 cubic metre of sand or other dry material suitable for quenching oil fires together with a scoop for its distribution, or alternatively, an additional portable fire extinguisher suitable for extinguishing oil fires.(3) In every ship of Class II(A) of less than 21.34 metres in length carrying more than 36 passengers, there shall be provided in addition to subregulation (2)- (a) in each space containing internal combustion type machinery use for main propulsion, or used for auxiliary purposes and having a total power of not less than 375 kilowatts with- (i) at least 2 water fog applicators; (ii) at least one set of portable foam applicator complying with the provisions of Schedule 6; and (iii) a fixed fire-extinguishing system complying with the requirements of regulation 7(1) by 1 October 2000;(b) in each boiler room not being part of the space in paragraph (a)- |