第8页 CAP 369X MERCHANT SHIPPING (SAFETY) (FIRE APPLIANCES) (SHIPS BUILT ON OR AFTER 25 MAY 1980 BUT BEFORE 1 SEPTEMBER 1984) REGULATIONS

[接上页]

  (i) at least 2 water fog applicators;
  
  (ii) at least one set of portable foam applicator unit complying with the provisions of Schedule 6; and
  
  (iii) a fixed fire-extinguishing system complying with the requirements of regulation 7(1) by 1 October 2000;(c) in each special category space-
  
  (i) at least 3 water fog applicators; and
  
  (ii) one set of portable foam applicator complying with the provisions of Schedule 6. Not less than 2 such applicators shall be available in the ship for use in any such space. (L.N. 412 of 1995)(4) In every ship of Class II(A) carrying more than 36 passengers, each member of the fire patrol shall be provided with a two-way portable radiotelephone apparatus. (L.N. 412 of 1995)
  
  (Enacted 1991)
  
  Cap 369X reg 19 Machinery spaces containing internal combustion type machinery
  
  (1) Every ship of Class II(A) of 15.24 metres in length or over but of less than 21.34 metres in length shall be provided in each space containing internal combustion type propelling machinery with at least 5 portable fire extinguishers suitable for extinguishing oil fires, and every ship of Class II(A) of less than 15.24 metres in length shall be provided with at least 3 such portable fire extinguishers in such spaces.
  
  (2) Every ship of Class II(A) of 15.24 metres in length or over but of less than 21.34 metres in length shall comply with regulation 18(3) and (4) as it applies to Class II(A) of less than 21. 34 metres.
  
  (Enacted 1991. L.N. 412 of 1995)
  
  Cap 369X reg 20 (No provision)
  
  No provision.
  
  (Enacted 1991)
  
  Cap 369X reg 21 (No provision)
  
  No provision.
  
  (Enacted 1991)
  
  Cap 369X reg 22 (No provision)
  
  No provision.
  
  (Enacted 1991)
  
  Cap 369X reg 23 (No provision)
  
  No provision.
  
  (Enacted 1991)
  
  Cap 369X reg 24 (No provision)
  
  No provision.
  
  (Enacted 1991)
  
  Cap 369X reg 25 (No provision)
  
  No provision.
  
  (Enacted 1991)
  
  Cap 369X reg 26 (No provision)
  
  No provision.
  
  (Enacted 1991)
  
  Cap 369X reg 27 (No provision)
  
  No provision.
  
  (Enacted 1991)
  
  Cap 369X reg 28 (No provision)
  
  No provision.
  
  (Enacted 1991)
  
  Cap 369X reg 29 (No provision)
  
  No provision.
  
  (Enacted 1991)
  
  Cap 369X reg 30 (No provision)
  
  No provision.
  
  (Enacted 1991)
  
  Cap 369X reg 31 Fire pumps, fire mains, water service pipes, hydrants, hoses and nozzles
  
  PART III
  
  SHIPS OTHER THAN PASSENGER SHIPS
  
  Ships of Class VII of 500 tons or over
  
  (1) Every ship of Class VII of 500 tons or over shall be provided with appliances in accordance with this regulation whereby at least 2 jets of water as required by these regulations can reach any part of the ship normally accessible to the passengers or crew while the ship is being navigated, and any store room and any part of any cargo space when empty.
  
  (2) (a) Every ship of Class VII of 1000 tons or over shall be provided with at least 2 fire pumps operated by power. Each such pump shall be capable of delivering at least one jet simultaneously from each of any 2 fire hydrants, hoses and nozzles provided in the ship and shall comply with the requirements of regulation 66.
  
  (b) Every ship of Class VII of 500 tons or over but under 1000 tons shall be provided with at least two fire pumps operated by power, each of which shall be capable of delivering at least one jet of water from any fire hydrants, hose and nozzle provided in the ship and shall comply with the requirements of regulation 66.(3) (a) If, in any ship of Class VII of 500 tons or over, a fire in any one compartment could put all the fire pumps out of action there shall be provided, in a position outside the machinery spaces, an independently driven power operated emergency fire pump and its source of power and sea connection.
  
  (b) In every such ship of 1000 tons or over the emergency fire pumps shall be capable of producing at least 2 sets of water from any of the fire hydrants and hoses through nozzles which shall comply with regulation 68(4)(b) while simultaneously maintaining a pressure of at least 2.1 kilograms per square centimetre (30 pounds per square inch) at any hydrant in the ship.
  
  (c) In every such ship of 500 tons or over but under 1000 tons, the emergency fire pump shall be capable of producing from any of the fire hydrants and hoses in the ship through a nozzle which shall comply with regulation 68(4)(a), a jet of water having a throw of not less than 12 metres (40 feet).(4) (a) In every ship of Class VII of 500 tons or over there shall be provided a fire main, water service pipes, hydrants, hoses and nozzles which shall comply with the requirements of regulations 67 and 68.
  
  (b) (i) Every such ship of 1000 tons or over shall, in addition to any fire hoses provided in the machinery spaces, be provided with at least one fire hose for each 30 metres length of the ship but in no case less than 5 hoses and such hoses shall have a total length of at least 60% of the length of the ship. In addition to such hoses there shall be provided one spare fire hose. In every such ship of 500 tons or over there shall be provided in ro / ro cargo spaces at least 3 water fog applicators in addition to the nozzles required by these regulations which shall be of the dual purpose type, incorporating a shut-off.