第3页 CAP 123F BUILDING (PLANNING) REGULATIONS

[接上页]

  (a) one-tenth of the width of the street; or
  
  (b) 3 m,whichever is the less:
  
  Provided that no portion of any such canopy shall be within 4.5 m, measured horizontally, of a line drawn vertically from a point in the centre line of the street nearest to such portion of the canopy. (L.N. 33 of 1966)
  
  (5) (Repealed L.N. 79 of 1992)
  
  (L.N. 54 of 1969; L.N 294 of 1976; L.N. 79 of 1992)
  
  Cap 123F reg 11 (Repealed L.N. 79 of 1992)
  
  Cap 123F reg 12 No doorways on to canopy
  
  No doorway giving direct access to the top of any canopy shall be made in the external wall of any building.
  
  Cap 123F reg 13 Use of verandahs or balconies
  
  Where any verandah or balcony has been built over or upon any street no such verandah or balcony shall be used or adapted to be used as a factory, workshop, storeroom, kitchen, lavatory, bathroom, water-closet, urinal or latrine.
  
  (L.N. 79 of 1992)
  
  Cap 123F reg 14 (Repealed L.N.57 of 1965)
  
  Cap 123F reg 15 Doors, etc. not to open over streets
  
  (1) Subject to paragraph (2), no door, gate, window or shutter opening on or over any street shall be so hung or placed as to project over such street at a height of less than 2.5 m above the ground.
  
  (2) Emergency exit doors, electrical transformer room doors, plant room doors, refuse storage chamber doors and doors leading to similar types of utility rooms or chambers may open outwards over such a street if such doors when fully opened do not cause an obstruction to any person or vehicle using the street.
  
  (L.N. 79 of 1992)
  
  Cap 123F reg 16 (Repealed L.N. 406 of 1987)
  
  PART III
  
  HEIGHTS, SITE COVERAGE, PLOT RATIO, OPEN SPACES AND LANES
  
  (L.N. 54 of 1969)
  
  Cap 123F reg 17 (Repealed L.N. 54 of 1969)
  
  Cap 123F reg 18 (Repealed L.N. 54 of 1969)
  
  Cap 123F reg 19 General provisions concerning site coverage and plot ratio
  
  (1) Where a site abuts on a street not less than 4.5 m wide or on more than one such street the maximum site coverage permitted in respect of a building or buildings to be erected thereon shall be determined in accordance with regulation 20 and the permitted plot ratio of such building or buildings shall be determined in accordance with regulation 21.
  
  (2) Where a site abuts on a street less than 4.5 m wide or does not abut on a street, the height of any building or buildings to be erected thereon and the maximum site coverage and plot ratio to be permitted in respect of such building or buildings shall be determined by the Building Authority.
  
  (L.N. 406 of 1987)
  
  Cap 123F reg 19A (Repealed L.N. 406 of 1987)
  
  Cap 123F reg 20 Permitted site coverage
  
  (1) Subject to regulation 22 and depending on the height of the building- (78 of 1970; L.N. 406 of 1987)
  
  (a) the site coverage for a domestic building, or for the domestic part of a composite building, on a class A site shall not exceed that percentage of the area of the site specified in the second column of the First Schedule;
  
  (b) the site coverage for a domestic building, or for the domestic part of a composite building, on a class B site shall not exceed that percentage of the area of the site specified in the third column of the First Schedule; and
  
  (c) the site coverage for a domestic building, or for the domestic part of a composite building, on a class C site shall not exceed that percentage of the area of the site specified in the fourth column of the First Schedule.(2) Subject to regulation 22 and paragraph (3) and depending on the height of the building- (L.N. 78 of 1970; L.N. 406 of 1987)
  
  (a) the site coverage for a non-domestic building, or for the non-domestic part of a composite building, on a class A site shall not exceed that percentage of the area of the site specified in the eighth column of the First Schedule;
  
  (b) the site coverage for a non-domestic building, or for the non-domestic part of a composite building, on a class B site shall not exceed that percentage of the area of the site specified in the ninth column of the First Schedule; and
  
  (c) the site coverage for a non-domestic building, or for the non-domestic part of a composite building, on a class C site shall not exceed that percentage of the area of the site specified in the tenth column of the First Schedule.(3) Subject to the provisions of paragraph (4), the site coverage for a non-domestic building, or for the non-domestic part of a composite building, on a class A, B or C site may, whatever the height of the building, exceed the permitted percentage site coverage to a height not exceeding 15 m above ground level. (L.N. 294 of 1976)
  
  (4) For the avoidance of doubt, it is hereby declared that, where pursuant to paragraph (3) the permitted percentage site coverage is exceeded-
  
  (a) above the level to which the permitted percentage site coverage is exceeded, the site coverage for the building or any part thereof shall not, subject to regulation 22, exceed the site coverage permitted under paragraph (1) or (2), as the case may be; and (L.N. 406 of 1987)
  
  (b) the plot ratio for the whole building shall not, subject to regulation 22, exceed the permitted plot ratio. (L.N. 406 of 1987)(5) In this regulation, the expression "permitted percentage site coverage" (准许上盖面积百分率) means the maximum site coverage permitted under paragraph (2).