第5页 CAP 123A BUILDING (ADMINISTRATION) REGULATIONS

[接上页]

  (b) structural calculations for supports where the Building Authority considers it appropriate;
  
  (c) a stability report with calculations demonstrating that the demolition works will not render inadequate the margin of safety of, or cause damage to, any building, structure, street, land and services;
  
  (d) a stability report with calculations demonstrating that the proposed use of equipment or mechanical plant will not render inadequate the margin of safety of, or cause damage to, any building, structure, street, land and services. (L.N. 514 of 1997; L.N. 608 of 1997)
  
  (e) (Repealed L.N. 608 of 1997)
  
  Cap 123A reg 9 Prescribed plans in respect of street works
  
  The plans set out hereunder are prescribed, for the purposes of the Ordinance and regulations, in respect of street works-
  
  (a) a key plan showing the site of the private street or access road;
  
  (b) a layout plan;
  
  (c) longitudinal sections, both vertical and horizontal;
  
  (d) cross sections; (L.N. 438 of 1990)
  
  (e) typical road sections; and (L.N. 438 of 1990)
  
  (f) in respect of any foundation and structural works for a street, a foundation plan showing the size the position of foundations together with a full report of the site investigation work undertaken and details of any grouting work to the ground proposed to be carried out and plans showing structural details together with one set of calculations for the structural works. (L.N. 438 of 1990)
  
  Cap 123A reg 10 Power of Building Authority to require additional plans, etc.
  
  The Building Authority may, where he considers it necessary, require additional plans, enlarged details, other documents and information regarding the supply of water, specifications of and the use of any special materials, or such other particulars as he may consider necessary.
  
  Cap 123A reg 11 Plans to be submitted in duplicate
  
  (1) Every plan submitted to the Building Authority for his approval shall be submitted in duplicate, and the Building Authority may require the submission of such additional copies of any such plan as he considers necessary. (L.N. 188 of 1974; L.N. 241 of 1976)
  
  (2) Every report of site investigation and all details of ground treatment work proposed in connexion with plans submitted to the Building Authority shall be submitted in duplicate. (L.N. 188 of 1974; L.N. 438 of 1990; L.N. 439 of 1990)
  
  Cap 123A reg 11A Foundation plan to be submitted with site formation plan
  
  In respect of building works in area number 1 of the scheduled areas, the foundation plan prescribed in regulation 8(1)(d) shall be submitted to the Building Authority for his approval with the site formation plan prescribed in regulation 8(1)(bb).
  
  (L.N. 233 of 1982; 52 of 1990 s. 11)
  
  Cap 123A reg 12 Plans, etc. to be signed by person who prepared them
  
  (1) Subject to paragraph (2), all plans, structural details and calculations submitted to the Building Authority for approval shall be prepared and signed by an authorized person, and his signature shall be deemed to be his assumption of all responsibility for the plan, structural details or calculations, as the case may be.
  
  (2) Subject to paragraph (3), all foundation plans, structural details and calculations required under regulations 8(1)(d) and (i) and 9(f) shall be prepared and signed by a registered structural engineer, and his signature shall be deemed to be his assumption of all responsibility for the plans, structural details or calculations, as the case may be.
  
  (3) In the case of building works to which paragraph (4) applies, all foundation plans, structural details and calculations required under regulation 8(1)(d) and (i) may be prepared and signed by an authorized person, and his signature shall be deemed to be his assumption of all responsibility for the plans, structural details or calculations, as the case may be.
  
  (4) Paragraph (3) applies to any building works where-
  
  (a) the height of the construction does not exceed 10 m;
  
  (b) the span of any structural element of the construction does not exceed 6 m;
  
  (c) the structural elements are constructed of timber, masonry, steel, plain concrete or reinforced concrete;
  
  (d) the foundations of the construction are of the spread footing type with a ground bearing pressure not exceeding 300 kPa and founded at not more than 2 m below existing ground level; and
  
  (e) there is no structural alteration to any existing structural elements designed by a registered structural engineer.
  
  (L.N. 438 of 1990)
  
  Cap 123A reg 13 Ratio of plans
  
  (1) Plans and sections of building works shall be drawn to a ratio of not less than 1:100:
  
  Provided that, in the case of very extensive building works, the Building Authority may accept plans drawn to a ratio of not less than 1:200.
  
  (2) (a) Every key plan submitted in respect of street works shall be drawn to a ratio of not less than 1:2500.
  
  (b) Every layout plan so submitted shall be drawn to a ratio of not less than 1:200.
  
  (c) Longitudinal sections so submitted shall-
  
  (i) if horizontal, be drawn to a ratio of not less than 1:500; and