[接上页] (11) A revocation or amendment of a certificate of competency by the Authority under subsection (4)(a) or (b), as the case may be, shall have immediate effect, notwithstanding any appeal lodged by the holder of the certificate against the decision under subsection (10). (Added 15 of 2002 s. 2) (Amended 87 of 1988 s. 35) Cap 56 s 7 Authority to keep certain registers, and particulars to be entered in register of boilers and pressure vessels (1) The Authority shall keep the following registers- (a) a register of boilers, pressure vessels, other than pressurized fuel containers, and steam containers; (Replaced 93 of 1970 s. 3) (b) a register of pressurized fuel containers; (c) a register of boiler inspectors and air receiver inspectors, in which shall be entered the name of every person who is appointed under section 5 to be a boiler inspector or an air receiver inspector; (Amended 87 of 1988 s. 7) (d) a register of pressurized fuel container inspectors, in which shall be entered the name of every person who is appointed under section 5 to be a pressurized fuel container inspector and his registration number which shall be allotted by the Authority; and (e) a register of competent persons, in which shall be entered the name of every person to whom a certificate of competency is issued under section 6, together with a statement as to the class or type of boiler or steam receiver that that person is for the time being competent to operate.(2) (a) The following particulars shall be recorded by the Authority in the register of boilers and pressure vessels in respect of each registered boiler or pressure vessel- (i) the name and address of the owner for the time being of the boiler or pressure vessel; (ii) except in the case of a boiler or pressure vessel that is designed so as to be transportable from one place to another, the address at which the boiler or pressure vessel is installed; (iii) the class or type of the boiler or pressure vessel; (iv) the registration number of the boiler or pressure vessel; (v) the maximum permissible working pressure of the boiler or pressure vessel notified to him in accordance with section 47(2); (vi) the maximum permissible working pressure of the boiler or pressure vessel specified in the current certificate of fitness issued in respect of the boiler or pressure vessel if the pressure therein specified differs from the maximum permissible working pressure notified to him in accordance with section 47(2) or entered in the register pursuant to paragraph (b); (vii) the date on which each certificate of fitness issued in respect of the boiler or pressure vessel was issued; and (viii) the making by the Authority of an order under section 32 in respect of the boiler or pressure vessel and the date (if any) on which the same ceased to be in force. (b) Where, upon an appeal under section 48, the maximum permissible working pressure of the boiler or pressure vessel determined by the Authority differs from the maximum permissible working pressure thereof determined by the appointed examiner from whose decision the appeal was made, the Authority shall delete the entry made in the register of boilers and pressure vessels in accordance with paragraph (a)(v) and enter in the register the maximum permissible working pressure determined by the Authority. (Amended 87 of 1988 s. 7) (c) The Authority shall delete from the register of boilers and pressure vessels the entry therein in respect of a boiler or pressure vessel if he is satisfied that it has been destroyed or is otherwise no longer being used in Hong Kong.(3) (a) The following particulars shall be recorded by the Authority in the register of pressurized fuel containers in respect of each registered pressurized fuel container- (i) the name and address of the owner for the time being of the pressurized fuel container; (ii) the place at which for the time being the pressurized fuel container is being used; (iii) the registration number of the pressurized fuel container; (iv) the making by the Authority of an order under section 32 in respect of the pressurized fuel container and the date (if any) on which the same ceased to be in force. (b) The Authority shall delete from the register of pressurized fuel containers the entry therein in respect of a pressurized fuel container if he is satisfied that it has been destroyed or is otherwise no longer being used in Hong Kong.(4) The Authority shall remove from the register of boiler inspectors and air receiver inspectors or the register of pressurized fuel container inspectors, as the case may be, the name of any person whose appointment to be a boiler inspector or an air receiver inspector or a pressurized fuel container inspector has been revoked and shall, during the continuance in force of a suspension of the appointment of a person to be a boiler inspector or an air receiver inspector or a pressurized fuel container inspector, keep in the register of boiler inspectors and air receiver inspectors or the register of pressurized fuel container inspectors, as the case may be, such entry as he considers sufficient to indicate the suspension. |