您所在位置:法邦网 > 法律法规 > 法规浏览

管理我的法规库

哇,我可以拥有自己的法规库!

法规提交

如果您发现我们没有收录到的法规,您可以在此提交。提交后我们会即时把它收录上,感谢您参与维护我们共同的法规库。
【法规名称】 
【法规编号】 61472  什么是编号?
【正  文】

第5页 CAP 369W MERCHANT SHIPPING (SAFETY) (FIRE PROTECTION) (SHIPS BUILT BEFORE 25 MAY 1980) REGULATIONS

[接上页]

  (Enacted 1991)
  
  Cap 369W reg 6 Fixed fire smothering arrangements in cargo spaces
  
  (1) In every ship of Class I or Class II of 1000 tons or over there shall be provided a fixed fire smothering gas installation complying with the requirements of regulation 65 which shall be so arranged as to protect every cargo space.
  
  (2) The Director may exempt any ship (other than a ship engaged in the carriage of dangerous goods of Classes 1 to 5) from the requirements of this regulation if he is satisfied that to require compliance therewith would be unreasonable on account of the short duration of the voyages on which the ship is engaged.
  
  (Enacted 1991)
  
  Cap 369W reg 7 Machinery spaces containing oil-fired boilers or oil burning equipment
  
  (1) In every ship of Class I or Class II there shall be provided for the protection of any space containing any oil-fired boiler, oil fuel settling tank or oil-fuel unit a fixed fire extinguishing installation of one of the following types-
  
  (a) a pressure water spraying system complying with the requirements or regulation 64;
  
  (b) a fire smothering gas installation complying with the requirements of regulation 65;
  
  (c) a foam fire extinguishing installation complying with the requirements of regulation 66.(2) If the engine and boiler spaces are not entirely separated from each other by a bulkhead, or if fuel oil can drain from the boiler space into the engine space, the combined engine and boiler spaces shall for the purpose of subregulation (1) be regarded as a single space.
  
  (3) In addition to the fixed installations required by subregulation (1) there shall be provided-
  
  (a) one or more foam fire extinguishers each of at least 135 litres capacity or one or more carbon dioxide fire extinguishers each of at least 45 kilograms capacity; the extinguishers shall be sited so as to be readily accessible in the event of fire and they shall be sufficient in number to enable foam or carbon dioxide as the case may be to be directed on to any part of the boiler space and spaces containing any part of the oil fuel installation;
  
  (b) in each firing space and in each space which contains any part of any oil fuel installation at least 2 portable fire extinguishers suitable for extinguishing oil fires; and
  
  (c) in each firing space either a receptacle containing at least 0.3 cubic metre of sand or other dry material suitable for quenching oil fires together with a scoop for its distribution, or a portable fire extinguisher suitable for extinguishing oil fires additional to those required by paragraph (b).(4) In every ship of Class I or Class II carrying more than 36 passengers there shall be provided in addition to the requirements of subregulation (1) in each boiler room with-
  
  (a) at least 2 water fog applicators; and
  
  (b) at least 1 portable foam applicator complying with Schedule 6. (L.N. 411 of 1995)(5) In every ship of Class I or Class II carrying more than 36 passengers there shall be provided in addition to the requirements of subregulation (1) in each special category space with at least 3 water fog applicators in addition to the nozzles required by these regulations. (L.N. 411 of 1995)
  
  (Enacted 1991)
  
  Cap 369W reg 8 Machinery spaces containing internal combustion type machinery
  
  (1) In every ship of Class I or Class II there shall be provided for the protection of any space containing internal combustion type machinery used for main propulsion, or used for auxiliary purposes and having a total power of not less than 746 kilowatts, at least one of the fixed fire extinguishing installations required by regulation 7(1).
  
  (2) In addition to the requirement of subregulation (1) there shall be provided in any space mentioned in that subregulation-
  
  (a) 1 foam fire extinguisher of at least 45 litres capacity or a carbon dioxide fire extinguisher of at least 16 kilograms capacity; and
  
  (b) 1 portable fire extinguisher suitable for extinguishing oil fires for each 746 kilowatts or part thereof of such machinery, provided that not less than 2 nor more than 6 such extinguishers shall be required in any such space.(3) In every ship of Class I or Class II carrying more than 36 passengers there shall be provided in addition to the requirements of subregulation (1) for machinery space containing internal combustion type machinery use for main propulsion, or used for auxiliary purposes and having a total power of not less than 746 kilowatts-
  
  (a) with at least 2 suitable water fog applicators; and
  
  (b) with at least 1 portable foam applicator. (L.N. 411 of 1995)
  
  (Enacted 1991)
  
  Cap 369W reg 9 Machinery spaces containing steam engines
  
  In every ship of Class I or Class II there shall be provided in spaces containing steam turbines or enclosed pressure lubricated steam engines used for main propulsion, or used for auxiliary purposes and having a total power of not less than 746 kilowatts-
  
  (a) foam fire extinguishers each of at least 45 litres capacity or carbon dioxide fire extinguishers each of at least 16 kilograms capacity sufficient in number and so sited as to enable the extinguishing medium to be directed on to any part of the pressure lubrication system and on to any part of the casings enclosing pressure lubricated parts of the turbines, engines or associated gearing; provided that such extinguishers shall not be required if equivalent protection is provided in such spaces by a fixed fire extinguishing installation fitted in compliance with regulation 7(1); and