[接上页] (b) 1 portable fire extinguisher, suitable for extinguishing oil fires, for each 746 kilowatts or part thereof of such machinery; provided that not less than 2 nor more than 6 such extinguishers shall be required in any such space and provided that such extinguishers shall not be required in addition to any required by regulation 8(2). (Enacted 1991) Cap 369W reg 9A Paint lockers, etc. In every ship of Class I and Class II, every paint locker and flammable liquid locker shall be protected by an approved fire-extinguishing system. (L.N. 411 of 1995) Cap 369W reg 10 Firemen's outfits (1) Every ship of Class I or Class II shall be provided with- (a) 2 firemen's outfits which shall include breathing apparatus of the air-hose type; and in addition (b) 2 firemen's outfits for every 80 metres (or part thereof) of the aggregate of the lengths of all passenger spaces and service spaces on the deck which carries such spaces or, if there is more than one such deck, on the deck which has the largest of such lengths; every such outfit shall comply with the requirements of regulation 69.(2) If in any ship of Class I or Class II which carries firemen's outfits containing only breathing apparatus of the air-hose type an air hose exceeding 36 metres in length would be necessary to reach from a point on the open deck well clear of any hatch or doorway to any part of the accommodation, service, cargo or machinery spaces, at least 2 sets of firemen's outfits provided pursuant to subregulation (1)(b) shall include breathing apparatus of the self-contained type. (Enacted 1991) Cap 369W reg 11 International shore connection Every ship of Class I or Class II of 1000 tons or over shall be provided with at least one international shore connection which shall comply with the requirements of Schedule 2 to enable water piped from another ship or shore to be connected to the fire main, and fixed provision shall be made to enable such a connection to be used on the port side and on the starboard side of the ship. (Enacted 1991) Cap 369W reg 12 Application of regulations 3(1) and 4 to 11 (ships of Class I or Class II) Expanded Cross Reference: 4, 5, 6, 7, 8, 9, 9A, 10, 11 Ships of Class II(A) of 21.34 metres in length or over (1) Regulations 3(1) and 4 to 11 inclusive shall apply to ships of Class II(A) of 21.34 metres in length or over as they apply to ships of Class I or Class II. <* Note - Exp. X-Ref.: Regulations 4, 5, 6, 7, 8, 9, 9A, 10, 11 *> (2) Regulation 3(6)(c), (e) and (f) shall apply to ships of Class II (A) of 21.34 metres in length or over and carrying more than 36 passengers as it applies to ships of Class I or Class II carrying more than 36 passengers. (3) In every ship of Class II(A) of 21.34 metres in length or over and carrying more than 36 passengers, a public address system or other effective means of communication shall be available and audible throughout the accommodation, public and service spaces, control stations and open decks not later than 1 October 1997. (Enacted 1991. L.N. 411 of 1995) Cap 369W reg 13 Fire pumps, fire main, water service pipes, hydrants, hoses and nozzles Ships of Class II(A) of less than 21.34 metres in length Every ship of Class II(A) of less than 21.34 metres in length shall be provided with a hand pump having a permanent sea connection and a hose with 2 nozzles. One such nozzle shall be 10 millimetres diameter. The pump shall be capable through such hose and nozzle of producing a jet of water which can be directed onto any part of the ship. All nozzles shall be a dual-purpose nozzle. Such pump shall be situated outside the machinery spaces. (Enacted 1991. L.N. 411 of 1995) Cap 369W reg 14 Portable fire extinguishers In every ship of Class II(A) of less than 21.34 metres in length at least one portable fire extinguisher shall be provided in each of the passenger spaces above the bulkhead deck, and at least 2 such extinguishers shall be provided in each of the crew spaces and each of the passengers spaces below that deck. At least one portable fire extinguisher shall be provided for use in any galley. (Enacted 1991) Cap 369W reg 15 Machinery spaces containing oil-fired boilers or oil burning equipment (1) In every ship of Class II(A) of less than 21.34 metres in length there shall be provided in any space containing any oil-fired boiler, oil fuel settling tank or oil-fuel unit one or more foam fire extinguishers each of at least 45 litres capacity or one or more carbon dioxide extinguishers each of at least 16 kilograms capacity. The extinguisher, or extinguishers, shall be sited so as to be readily accessible in the event of fire and they shall be sufficient in number to enable foam or carbon dioxide as the case may be to be directed on to any part of the boiler room or spaces containing any part of the oil fuel installation. (2) In addition to the extinguishers required by subregulation (1) there shall be provided- (a) in each firing space and in each space which contains any part of any oil fuel installation at least 2 portable fire extinguishers suitable for extinguishing oil fires; and |