第10页 CAP 369B MERCHANT SHIPPING (FIRE APPLIANCES) REGULATIONS

[接上页]

  (4) Except in partially decked ships of Group 5 and in ships of Class X and XII, fire hoses provided in compliance with these regulations shall not be used for any purpose other than extinguishing fire or testing with fire appliances.
  
  (5) Every ship which is required by these regulations to be provided with fire pumps operated by power shall be provided with nozzles of 1/2 inch, 5/8 inch or 3/4 inch in diameter or as near thereto in diameter as possible.
  
  (6) Nozzles larger in diameter may be provided if the requirements of these regulations relating to the provision of water for fire fighting purposes are otherwise complied with.
  
  (7) For machinery spaces and exterior locations the diameter of the nozzles shall be such as to obtain the maximum possible discharge from the minimum number of jets of water and at the pressure required by these regulations from the smallest fire pump permitted by paragraph (5) of regulation 32:
  
  Provided that the diameter of the nozzles shall not be required to be greater than 3/4 inch.
  
  (8) For accommodation and service spaces the diameter of the nozzles shall not be required to be greater than 1/2 inch.
  
  (9) Every spray nozzle provided in compliance with these regulations shall be capable of producing a water spray suitable for extinguishing oil fires and shall be provided in addition to any plain nozzle required by paragraph (2):
  
  Provided that a dual-purpose nozzle capable of producing alternately such a spray and a plain water jet may be provided in substitution.
  
  Cap 369B reg 35 International shore connection
  
  Any international shore connection provided in compliance with these regulations shall be constructed in accordance with the requirements of the First Schedule.
  
  Cap 369B reg 36 Fire extinguishers
  
  (1) Non-portable foam and carbon dioxide fire extinguishers provided in compliance with these regulations shall be constructed in accordance with the requirements of the Second and Third Schedules, respectively.
  
  (2) Portable fire extinguishers (other than carbon dioxide fire extinguishers) provided in compliance with these regulations shall, if they are of a type discharging fluid, have a capacity of not more than 3 and not less than 2 imperial gallons.
  
  (3) Portable carbon dioxide fire extinguishers provided in compliance with these regulations shall have a capacity of not less than 7 lb. of carbon dioxide.
  
  (4) Portable dry powder fire extinguishers provided in compliance with these regulations shall have a capacity of not less than 10 lb. of dry powder.
  
  (5) Portable fire extinguishers of other types provided in compliance with these regulations shall be of not less than the fire extinguishing equivalent of a 2 gallon fluid fire extinguisher.
  
  (6) Portable fire extinguishers provided in compliance with these regulations shall not exceed 56 lb. in weight in the fully charged service condition and shall be as portable as a 3 gallon fluid fire extinguisher.
  
  (7) Portable fire extinguishers provided in compliance with these regulations for use in accommodation or service spaces of any ship shall so far as practicable have a uniform method of operation.
  
  (8) Portable fire extinguishers provided in compliance with these regulations shall, subject to the limitations of paragraphs (2), (3), (4), (5), (6) and (7), be constructed in accordance with the following specifications of the British Standards Institution-
  
  Type of Extinguisher
  
  Specification Number
  
  Water type (Soda-acid)......................
  
  B.S. 138: 1948
  
  Water type (Gas-pressure) ................
  
  B.S. 1382: 1948
  
  Foam type (Chemical) .......................
  
  B.S. 740: Part 1: 1948
  
  Foam type (Gas-pressure) .................
  
  B.S. 740: Part 2: 1952
  
  Carbon dioxide ..................................
  
  B.S. 3326: 1960
  
  Dry powder ......................................
  
  B.S. 3465: 1962(9) Where portable dry powder fire extinguishers are provided in compliance with these regulations in either accommodation and service spaces or in machinery spaces their number shall not exceed one half of the total number of extinguishers provided in either of those spaces.
  
  (10) Fire extinguishers provided for use in any ship to which these regulations apply shall not contain an extinguishing medium which either itself or when in use gives off gases harmful to persons.
  
  (11) For the purposes of these regulations the capacity of any fire extinguisher other than a carbon dioxide fire extinguisher shall be taken to be the greatest volume or weight of extinguishing medium which it can contain when sufficient space is left to ensure the proper operation of the extinguisher.
  
  (12) For the purposes of these regulations the capacity of a carbon dioxide fire extinguisher shall be taken to be the greatest weight of carbon dioxide which it can safely contain in a tropical climate.
  
  (13) Every fire extinguisher provided in compliance with these regulations shall be kept fully charged at all times.
  
  (14) A spare charge shall be provided for every portable fire extinguisher provided in compliance with these regulations, except that for each such fire extinguisher which is of a type that cannot readily be recharged while the ship is at sea, an additional portable fire extinguisher of the same type, or its equivalent, shall be provided in lieu of a spare charge.