第3页 CAP 369B MERCHANT SHIPPING (FIRE APPLIANCES) REGULATIONS

[接上页]

  (b) in addition, at least one portable fire extinguisher in every galley.(2) In every such ship at least one portable fire extinguisher shall be provided for use in each control station.
  
  Cap 369B reg 9 Ships of Group 2: Fixed fire smothering arrangements in cargo spaces
  
  (1) In every ship of Group 2 of 1000 tons or over there shall be provided a fixed fire smothering gas installation complying with the requirements of regulation 39 which shall be so arranged as to protect every cargo space.
  
  (2) The Director may exempt any ship from the requirements of this regulation if he is satisfied that to require compliance therewith would be unreasonable on account of the short duration of the voyages on which the ship is engaged, or that the holds therein are provided with steel hatch covers and effective means of closing all ventilators and other openings leading to the holds.
  
  Cap 369B reg 10 Ships of Group 2: Machinery spaces containing oil-fired boilers or oil burning equipment
  
  (1) In every ship of Group 2 there shall be provided for the protection of any space containing any oil-fired boiler, oil fuel settling tank or oil fuel unit at least one of the following fixed fire extinguishing installations-
  
  (a) a pressure water spraying system complying with the requirements of regulation 38;
  
  (b) a fire smothering gas installation complying with the requirements of regulation 39; and
  
  (c) a foam fire extinguishing installation complying with the requirements of regulation 40:Provided that if the engine and boiler rooms are not entirely separated from each other by a bulkhead, or if fuel oil can drain from the boiler room into the engine room, the combined engine and boiler rooms shall, for the purpose of this paragraph, be regarded as a single space.
  
  (2) In addition to the requirement of paragraph (1) there shall be provided-
  
  (a) in each boiler room one or more foam fire extinguishers each of at least 30 gallons capacity or carbon dioxide fire extinguishers each of at least 100 lb. capacity, so sited as to be readily accessible in the event of fire and sufficient in number to enable foam or carbon dioxide to be directed on to any part of the boiler room and spaces containing any part of the oil fuel installation;
  
  (b) in each firing space and in each space which contains any part of any oil fuel installation at least two portable fire extinguishers suitable for extinguishing oil fires; and
  
  (c) in each firing space a receptacle containing at least 10 cubic feet of sand or other dry material suitable for quenching oil fires together with a scoop for its distribution, or alternatively an additional portable fire extinguisher suitable for quenching oil fires.
  
  Cap 369B reg 11 Ships of Group 2: Machinery spaces containing internal combustion type machinery
  
  (1) In every ship of Group 2 there shall be provided for the protection of any space containing internal combustion type machinery used for main propulsion, or having in the aggregate a total power of not less than 1000 b.h.p. for auxiliary purposes, at least one of the fixed fire extinguishing installations required by paragraph (1) of regulation 10.
  
  (2) In addition to the requirements of paragraph (1) there shall be provided in any such space-
  
  (a) one foam fire extinguisher of at least 10 gallons capacity or a carbon dioxide fire extinguisher of at least 35 lb. capacity; and
  
  (b) one portable fire extinguisher suitable for extinguishing oil fires for each 1000 b.h.p. or part thereof of such machinery but in no event less than two such extinguishers:
  
  Provided that not more than six such extinguishers shall be required in any such space.
  
  Cap 369B reg 12 Ships of Group 2: Machinery spaces containing steam engines
  
  In every ship of Group 2 there shall be provided in spaces containing steam turbines or enclosed pressure lubricated steam engines used either for main propulsion, or having in the aggregate a total power of not less than 1000 b.h.p. for auxiliary purposes-
  
  (a) foam fire extinguishers each of at least 10 gallons capacity or carbon dioxide fire extinguishers each of at least 35 lb. capacity sufficient in number to enable foam or carbon dioxide to be directed on to any part of the pressure lubrication system and on to any part of the casings enclosing pressure lubricated parts of the turbines, engines or associated gearing, if any:
  
  Provided that such extinguishers shall not be required if equivalent protection is provided in such spaces by a fixed fire extinguishing installation fitted in compliance with paragraph (1) of regulation 10 or paragraph (1) of regulation 11 ; and(b) one portable fire extinguisher for each 1000 b.h.p. or part thereof of such machinery, suitable for extinguishing oil fires, but in no event less than two such extinguishers:
  
  Provided that-
  
  (i) not more than six such extinguishers shall be required in any one such space; and
  
  (ii) such extinguishers shall not be required in addition to any provided in compliance with paragraph (2) of regulation 11.