[接上页] (16) In addition to the requirements of paragraph (15) there shall be provided in any such space- (a) one foam fire extinguisher of at least 10 gallons capacity or a carbon dioxide fire extinguisher of at least 35 lb. capacity; and (b) one portable fire extinguisher for extinguishing oil fires for each 100 b.h.p. or part thereof of such machinery: Provided that no more than six such extinguishers shall be required in any such space.(17) Every ship to which this regulation applies shall be provided with at least one fireman's outfit which shall comply with the requirements of regulation 42, and which shall contain a breathing apparatus of the air hose type. Cap 369B reg 29 Ships of Group 7 of under 500 tons (1) This regulation applies to ships of Group 7 of under 500 tons. (2) Every ship to which this regulation applies shall be provided with appliances in accordance with this regulation whereby at least one jet of water as required by these regulations can reach any part of the ship normally accessible to the crew while the ship is being navigated and any store room and any part of the cargo space when empty. (3) Every such ship shall be provided with at least one fire pump operated by power which shall be capable of delivering at least one jet of water from any fire hydrant, hose and nozzle provided in the ship and which shall comply with the requirements of regulation 32. (4) In every such ship fitted with oil-fired boilers or internal combustion type propelling machinery, if the pump required by paragraph (3) and its source of power and sea connection are not situated outside spaces containing such boilers or machinery, there shall be provided in a position outside such spaces an additional fire pump and its source of power and sea connection; and if any such pump is operated by power, it shall comply with the requirements of paragraph (3) and if it is manually operated, it shall be provided with a hose and 3/8 inch diameter nozzle through which it shall be capable of producing a jet of water having a throw of not less than 20 feet which can be directed on to any part of the ship. (5) In every such ship there shall be provided a fire main, water service pipes and hydrants which shall comply with the requirements of regulation 33 and at least two fire hoses. (6) In every such ship fitted with oil-fired boilers or internal combustion type propelling machinery there shall be provided a spray nozzle suitable for use with the fire hoses required by paragraph (5). (7) Every ship to which this regulation applies shall be provided with at least two portable fire extinguishers so situated as to be readily available for use in the accommodation and service spaces. (8) In every such ship there shall be provided for the protection of any space containing any oil-fired boiler, oil fuel settling tank or oil fuel unit at least one of the following fixed fire extinguishing installations- (a) a pressure water spraying system complying with the requirements of regulation 38; (b) a fire smothering gas or steam installation complying with the requirements of regulation 39; or (c) a foam fire extinguishing installation complying with the requirements of regulation 40,and if the engine and boiler rooms are not entirely separated from each other by a bulkhead, or if fuel oil can drain from the boiler room into the engine room, the combined engine room and boiler room shall, for the purpose of this paragraph, be regarded as a single space. (9) In addition to the requirements of paragraph (8), there shall be provided- (a) in each boiler room and in each space which contains any part of any oil fuel installation, at least two portable fire extinguishers suitable for extinguishing oil fires; and (b) in each firing space a receptacle containing at least 5 cubic feet of sand or other dry material suitable for quenching oil fires together with a scoop for its distribution, or alternatively an additional portable fire extinguisher suitable for extinguishing oil fires.(10) In every ship to which this regulation applies there shall be provided in any space containing internal combustion type propelling machinery used for main propulsion or having such machinery for auxiliary purposes, at least one of the fixed fire extinguishing installations required by paragraph (8). (11) In addition to the requirements of paragraph (10) there shall be provided in any such space one portable fire extinguisher suitable for extinguishing oil fires for each 100 b.h.p. or part thereof of such machinery, except that no more than six such extinguishers shall be required in any one space and that alternatively there may be provided two such extinguishers together with either- (a) one foam fire extinguisher of at least 10 gallons capacity; or (b) one carbon dioxide fire extinguisher of at least 35 lb. capacity.(12) Every ship to which this regulation applies shall be provided with at least one fireman's outfit which shall comply with the requirements of regulation 42, and which shall contain a breathing apparatus of the air hose type. |