第2页 CAP 369B MERCHANT SHIPPING (FIRE APPLIANCES) REGULATIONS

[接上页]

  (3) These regulations apply to British ships registered in Hong Kong and to other ships while they are within any port of Hong Kong.
  
  (4) These regulations shall not apply to-
  
  (a) a ship by reason of her being within a port of Hong Kong if she would not have been in any such port but for stress of weather or any other circumstances that neither the master nor the owner nor the charterer (if any) of the ship could have prevented or forestalled; or
  
  (b) pleasure yachts which are not passenger steamers and are of less than 45 feet in length.
  
  Cap 369B reg 4 Classification of ships
  
  For the purpose of these regulations, ships to which the regulations apply shall be arranged in the following groups-
  
  (a) Group 1 ships, being ships of Class I and II as defined in the Rules;
  
  (b) Group 2 ships, being Simla Rule Ships and other ships of Class G as defined in the Merchant Shipping (Life Saving Appliances) Regulations (Cap 369 sub. leg.);
  
  (c) Group 3 ships, being ships of Class VII, VIIA, VIII and VIIIA as defined in the Rules;
  
  (d) Group 4 ships, being ships of Class IX, IXA and X as defined in the Rules;
  
  (e) Group 5 ships, being launches and ferry vessels;
  
  (f) Group 6 ships, being ships of Class XI and XII as defined in the Rules; and
  
  (g) Group 7 ships, being tankers and operating either within the waters of Hong Kong or solely within the river trade limits.
  
  Cap 369B reg 5 Ships of Group 1: Application
  
  PART II
  
  PASSENGER STEAMERS
  
  The Rules applicable to ships of Class I and II shall apply to ships of Group 1 as they apply to ships of Class I and II.
  
  Cap 369B reg 6 Ships of Group 2: Fire patrol and detection systems
  
  (1) In every ship of Group 2 an efficient patrol system shall be maintained so that any outbreak of fire may be promptly detected.
  
  (2) In every ship of Group 2 there shall be provided in any part of the ship which is not accessible to the fire patrol a fire detection system complying with the requirements specified in regulation 41.
  
  (3) The Director may exempt any ship from the requirements of paragraph (2) if he is satisfied that to require compliance therewith would be unreasonable on account of the short duration of the voyage on which the ship is engaged.
  
  Cap 369B reg 7 Ships of Group 2: Fire pumps, fire main, water service pipes, hydrants, hoses and nozzles
  
  (1) Every ship of Group 2 shall be provided with appliances in accordance with this regulation whereby at least two jets of water as required by these regulations can reach any part of the ship normally accessible to the passengers or crew while the ship is being navigated and any store room and any part of the cargo space when empty.
  
  (2) Every ship of Group 2 of 4000 tons or over shall be provided with at least three fire pumps operated by power and every such ship of under 4000 tons shall be provided with at least two such pumps.
  
  (3) Every pump referred to in paragraph (2) shall be capable of delivering at least one jet simultaneously from each of any two hydrants, hoses and nozzles provided in the ship and shall comply with the requirements of regulation 32.
  
  (4) If in any ship of Group 2 a fire in any one compartment could put all the fire pumps out of action, there shall be provided, in a position outside the machinery spaces, an independently driven power operated emergency fire pump and its source of power and sea connection.
  
  (5) Every emergency fire pump referred to in paragraph (4) shall be capable of producing at least two jets of water from any two hydrants and hoses through nozzles which shall comply with paragraph (7) of regulation 34, while simultaneously maintaining a pressure of at least 30 pounds per square inch at any hydrant in the ship.
  
  (6) In every ship of Group 2 there shall be provided a fire main, water service pipes, hydrants, hoses and nozzles which shall be so arranged that they comply with the requirements of regulations 33 and 34, when all watertight and fire resisting doors are closed.
  
  (7) In every ship of Group 2 at least one fire hose shall be provided for every hydrant fitted in compliance with these regulations.
  
  (8) In every ship of Group 2 fitted with oil-fired boilers or internal combustion type propelling machinery there shall be provided in each space containing such boilers or machinery at least two fire hydrants, one on the port side and one on the starboard side.
  
  (9) In addition to the requirements prescribed in paragraph (8), in respect of any ship referred to in that paragraph in which there is access to the machinery space by way of a shaft tunnel-
  
  (a) a fire hydrant shall be provided in the tunnel at the end adjacent to that space; and
  
  (b) a spray nozzle shall be provided for every hydrant fitted in such spaces in compliance with these regulations.
  
  Cap 369B reg 8 Ships of Group 2: Portable fire extinguishers in accommodation and service spaces
  
  (1) Every ship of Group 2 shall be provided with-
  
  (a) a sufficient number of portable fire extinguishers to ensure that at least one such extinguisher will be readily available for use in each of the passenger spaces above the bulkhead deck and with at least two such extinguishers in each of the crew spaces and of the passenger spaces below that deck; and