[接上页] Administration, thereby impaired." Regulation 15 Openings in watertight bulkheads in passenger ships The existing text of this regulation is replaced by the following: "Openings in watertight bulkheads in passenger ships (This regulation applies to ships constructed on or after 1 February 1992) 1 The number of openings in watertight bulkheads shall be reduced to the minimum compatible with the design and proper working of the ship; satisfactory means shall be provided for closing these openings. 2.1 Where pipes, scuppers, electric cables, etc., are carried through watertight subdivision bulkheads, arrangements shall be made to ensure the watertight integrity of the bulkheads. 2.2 Valves not forming part of a piping system shall not be permitted in watertight subdivision bulkheads. 2.3 Lead or other heat sensitive materials shall not be used in systems which penetrate watertight subdivision bulkheads, where deterioration of such systems in the event of fire would impair the watertight integrity of the bulkheads. 3.1 No doors, manholes, or access openings are permitted: .1 in the collision bulkhead below the margin line; .2 in watertight transverse bulkheads dividing a cargo space from an adjoining cargo space or from a permanent or reserve bunker, except as provided in paragraph 10.1 and in regulation 16. 3.2 Except as provided in paragraph 3.3, the collision bulkhead may be pierced below the margin line by not more than one pipe for dealing withfluid in the forepeak tank, provided that the pipe is fitted with a screwdown valve capable of being operated from above the bulkhead. The Administration may, however, authorize the fitting of this valve on the after side of the collision bulkhead provided that the valve is readily accessible under all service conditions and the space in which it is located is not a cargo space. 3.3 If the forepeak is divided to hold two different kinds of liquids the Administration may allow the collision bulkhead to be pierced below the margin line by two pipes, each of which is fitted as required by paragraph 3.2, provided the Administration is satisfied that there is nopractical alternative to the fitting of such a second pipe and that, having regard to the additional subdivision provided in the forepeak, the safety of the ship is maintained. 4.1 Watertight doors fitted in bulkheads between permanent and reserve bunkers shall always be accessible, except as provided in paragraph 9.4 for between-deck bunker doors. 4.2 Satisfactory arrangements shall be made by means of screens or otherwise to prevent the coal from interfering with the closing of watertight bunker doors. 5 Subject to paragraph 11, not more than one door, apart from the doors to bunkers and shaft tunnels, may be fitted in each main transverse bulkhead within spaces containing the main and auxiliary propulsion machinery including boilers serving the needs of propulsion and all permanent bunkers. Where two or more shafts are fitted, the tunnels shall be connected by an intercommunicating passage. There shall be only one door between the machinery space and the tunnel spaces where two shafts are fitted and only two doors where there are more than two shafts. All these doors shall be of the sliding type and shall be so located as to have their sills as high as practicable. The hand gear for operating these doors from above the bulkhead deck shall be situated outside the spaces containing the machinery. 6.1 Watertight doors, except as provided in paragraph 10.1 or Regulation 16, shall be power-operated sliding doors complying with the requirements of paragraph 7 capable of being closed simultaneously from the central operating console at the navigating bridge in not more than 60 seconds with the ship in the upright position. 6.2 The means of operation whether by power or by hand of any power-operated sliding watertight door shall be capable of closing the door with the ship listed to 15° either way. Consideration shall also be given to the forces which may act on either side of the door as may be experienced when water is flowing through the opening applying a static head equivalent to a water height of at least 1 m above the sill on the centreline of the door. 6.3 Watertight door controls, including hydraulic piping and electric cables, shall be kept as close as practicable to the bulkhead in which the doors are fitted, in order to minimize the likelihood of them being involved in any damage which the ship may sustain. The positioning of watertight doors and their controls shall be such that if the ship sustains damage within one fifth of the breadth of the ship, as defined in Regulation 2, such distance being measured at right angles to the centreline at the level of the deepest subdivision load line, the operation of the watertight doors clear of the damaged portion of the ship is not impaired. 6.4 All power-operated sliding watertight doors shall be provided with |